Halyard Roofing

08Overlay over the old shingles — declined$0.00

08 · Flat and low-slope

Under 2:12,
shingles are
the wrong answer

Lanais, porch roofs, carports and additions are often built with almost no fall at all, and then shingled anyway because the rest of the house is shingled. On a low slope, water sits and moves sideways, and a shingle roof is a lapped system that assumes water only ever runs down.

SEAMMEMBRANE OVER INSULATION

Low-slope

Shingle limit
2:12 with doubled underlayment. Below that, no shingles
System
Two-ply self-adhered modified bitumen, granulated cap
Flashlight or kettle
Neither. Self-adhered only
Wall termination
Membrane up at least 8″, into a reglet or behind siding
Transition
Shingles above lap over the membrane, never under
Ponding
Water still standing after ~48 hours means fall, not membrane
Penetrations
Boot, curb or filled pitch pan. Not mastic
Coatings
A system on a flat roof. Paint on shingles
A low-slope roof section, seams and drain visible
A low-slope roof — a stock photograph of the trade, not a job of ours.

Where the line actually is

Shingle manufacturers allow their product down to 2:12 — two inches of rise per foot — and only then with a doubled underlayment or a fully self-adhered base. Below 2:12 the instructions do not permit shingles at all, so a shingled low-slope roof is out of warranty from the day it is finished, whatever anyone told the homeowner.

Plenty of Florida porch roofs are 1:12 or flatter. If yours is shingled and it leaks in every heavy rain rather than in every rain, this is usually why: water backs up at the laps, gets under them and travels.

What we use instead

Self-adhered modified bitumen, in two plies: a base sheet and a granulated cap sheet, fully bonded, with the laps rolled. It is quiet, there is no flashlight and no kettle anywhere near your house, and the granulated surface takes Florida sun far better than a smooth membrane. On a small lanai it is a day's work.

Where a single-ply makes more sense — a bigger deck, a roof somebody walks on — we will say so, and if it is a size or a detail that wants a commercial crew we will tell you that instead of improvising on your house.

The transition, which is where these leak

Almost every low-slope failure we are called to is not out in the field of the membrane. It is at the point where the flat section meets the shingled roof above it, or where it dies into a wall.

Done properly, the membrane runs up the vertical face at least eight inches and is terminated — either into a reglet cut in the masonry, or behind the siding, or under a counterflashing — and the shingles above lap down over the top of it, not the other way round. Done quickly, the membrane is cut off at the joint and a bead of sealant is run along it. That joint is the lowest point of the whole assembly and the sealant is the only thing holding it.

Ponding

Water standing on a flat roof more than about forty-eight hours after rain is ponding, and it is a structural and drainage problem rather than a membrane problem. Membrane will tolerate it for a while, but it grows algae, it accelerates the surface, and it is dead weight where the deck already sags. The fix is either tapered insulation to build fall into the surface, or a drain or scupper in the right place. Recovering a ponding roof with a new membrane and no change to the fall just buys you time at a poor exchange rate.

Penetrations on a flat roof

Every pipe, conduit, condenser stand and cable through a low-slope roof needs a proper detail: a boot, a curb, or a pitch pan filled and topped. A pitch pan is legitimate and it is also the one detail that needs looking at every couple of years, because the filler shrinks. Anything that has been made watertight with a mound of black mastic is a leak that has not happened yet.

Coatings

On a flat roof, a coating is a real system with a real specification — a sound substrate, proper preparation, a stated dry film thickness and a warranty from the coating manufacturer. It can be a sensible way to extend a membrane that is intact but tired. It is not a way to fix a roof that is already leaking, and it is not something to spray on a wet or ponding surface, whatever the man with the truck says. On shingles, as we say elsewhere, a coating is simply paint.